Savannah, GA grease trap & interceptor requirements
Quoted from official source Last checked 2026-10-17. Report an error / rule changed
Quick answer
- How often to pump: Before grease + solids reach 25% of depth/capacity
- Interceptor minimum / sizing: not stated in the sources we checked
- Permit / fees: Permit required
Rules change; verify with your city. Summaries are plain-English restatements of the official source linked below; “Source says” shows the exact wording. Blank rows mean the sources we checked did not state that rule, not that there is no rule.
| Required trap / interceptor type | Source says: “City of Savannah approval of flow control devices and grease interceptor design must be given prior to installation. c.” |
|---|---|
| Sizing rule | Source says: “The grease retention capacity rating in pounds shall be at least two (2) times the GPM flow rate of the type fixture which it serves.” |
| Pumping / cleaning frequency | Pump before grease + solids reach 25% of depth/capacity. Source says“Maintenance of grease interceptors must include thorough pump-out and/or cleaning as needed, (whenever 25% or more of the grease trap becomes full of grease and/or solids as determined by the measured depth), with a minimum frequency of four (4) times per year.” |
| Permit required? | A permit is required (see source wording). Source says“The administrator may require septic tank waste haulers to obtain wastewater discharge permits.” |
| Permit & program fees | Not stated in the sources we checked |
| Inspections | Grease traps/interceptors are subject to inspection. Source says“All grease interceptors shall be designed and installed in accordance with this standard to allow for complete access to inspection, maintenance, etc.” |
| Record keeping | Not stated in the sources we checked |
| Pumper / hauler approval | Use an approved / licensed grease hauler. Source says“The LGA shall implement the issuance of a transporter permit to all commercial waste transporters that removes fat, oils and grease from a waste generator and transports such waste in their tank trucks to dispose of waste at an EPD-approved site.” |
| Reporting portal | Not stated in the sources we checked |
| Fines & penalties | Not stated in the sources we checked |
| Program contact | Not stated in the sources we checked |
Sources
- https://www.savannahga.gov/DocumentCenter/View/89/Grease-Interceptor-Standard?bidId= · checked 2026-10-17
- https://agenda.savannahga.gov/content/files/sewer-use-and-pretreatment-ordinance-changes.pdf · checked 2026-10-17
Find a grease trap pumper in Savannah
Compare pumpers that service Savannah and check they meet the city's hauler rules above. Directory coming soon.
Get notifiedPump grease traps in Savannah?
Put your company in front of restaurants checking these rules. Featured listing (paid) – coming soon.
List your companySize your interceptor
Use the grease interceptor sizing calculator (UPC, IPC and PDI methods), then confirm Savannah's own minimums above. Not sure how often to pump? Read how often to pump a grease trap.
Other Georgia programs
Grease rule changes, once a week